2014 Ford Escape Bearing. RETAINER. Wheel. Snap. W/O ... - 2014 ford escape front wheel bearing
• Live Move: RotAlign offers Live Move functionality in both vertical and horizontal planes, enabling real-time adjustments and immediate feedback during the alignment process.
The motor end bell was removed and the motor bearings and grease cavity were packed 100 percent full of the test grease for all test conditions to increase the severity of the test.
PRUFTECHNIK’s laser alignment kits have helped Mun Siong Engineering to successfully complete over 100 installations, after sales services and workshop overhauls within a year.
In the early 1990s, DuPont entered into a preferred supplier alliance with an internationally known manufacturer of high-quality electric motors to provide new and/or replacement motors manufactured to the IEEE 841 standard. These 841-compliant NEMA-frame horizontal motors are equipped with open ball bearings, grease relief valves and rotating labyrinth seals on both bearing housings. In addition, motors were equipped with a patented bearing housing design to provide positive lubrication of motor bearings for long, trouble-free lives.
• Robust hardware: Designed with IP65 industrial-grade materials, making it suitable for harsh working environments and ensuring durability and longevity.
Inspection showed a substantial amount of grease pushed through the outboard shield, the rotating bearing elements and the inboard shield, and entering the motor winding cavity. These findings were somewhat surprising as well as troubling, because this arrangement was thought to provide the best system to prevent overalubrication.
Due to temperature differences across the bearing housing and grease shearing in the ball path zone, undisturbed grease in the end bell at the exit port acts as a plug, preventing excess grease from exiting the bearing housing, whether or not a grease relief valve is present.
Adding a measured amount of grease at regular intervals should minimize the amount of grease getting into the windings without adverse affects on motor life.
• Complete system: A single tool for standard alignments, advanced applications, and software analysis that provides maximum return on investment (ROI) for users
In this impromptu test, an industry-leading polyurea grease was added to the bearing housing of a newly rebuilt electric motor. The motor, equipped with double-shielded deep-groove bearings was operating at normal speed and ambient shop temperature. Grease was added slowly from a hand-operated grease gun until grease exited the bearing housing 1/8-inch NPT relief port opening. Once grease was observed at the exit port, the motor was stopped, disassembled and inspected for the presence of excess grease.
Easy-Laser XT440
Neither the Reliance positive lubrication system (PLS) with open bearings nor potentially other motors equipped with shielded bearings can prevent the ingression of grease into the motor windings.
The ROTALIGN touch with its larger detector, move simulator and ease of use has made the alignments in the Test Cell that much easier. Given the use of turn buckles on the inboard end of the engine for adjustment, the ability in the ROTALIGN touch to show both vertical and horizontal adjustments live at the same time is essential.
After approximately 1 minute on-screen message box appears stating new upgrade firmware found. Tap green tick button to start upgrade. Remove USB memory stick from the touch device.
• Fluke Reliability extended warranty: Gain peace of mind, convenience, device accuracy, and savings on service costs via 2 – 5 year mfg. warranty, 3 free calibrations, and 15% discount on repairs.
DuPont lubrication standard "PL 43 - Lubrication of Electric Motors" provides detailed guidance on acceptable lubricants and lubrication methods for electric motors, both grease and oil-lubricated. This article focuses on grease- lubricated NEMA-frame motors between 10 and 200 horsepower typically used to drive process pumps, mixer gearboxes, cooling tower pumps and fans, and other nonprocess-critical general-purpose applications.
The consistency of the grease was found to be soft and drippy, suggesting loss of structural stability of the soap structure. It was not determined if this loss of stability was temporary or permanent.
Again, the temperature increased rapidly over 20°F in the first minute of operation and then slowly increased over the next 40 minutes to approximately 175°F as seen in the previous Test Condition 3. However, the equalization time for this lubrication method is much closer to the generally accepted 30 minutes purge time contained in the standard and generally accepted within the industry.
Also, the grease was absolutely fresh, whereas, long-life in-service motors could potentially have hardened or dried grease, possibly adding more restriction in the outlet path. Based on these factors, we felt additional testing on the new 841 design motor was warranted to determine the effectiveness of this design in preventing overlubrication and motor winding contamination.
With sensALIGN 7, the door to the toughest alignment applications opens wide. Intelligent alignment features make it possible to approach complex alignments with serenity: intelliSWEEP filters out any poor measurement data due to difficult measuring conditions.
RotAlign Touch is the flagship laser alignment tool from Prüftechnik, a complete system that delivers maximum value and ROI for your alignment work. • High-precision adaptive alignment, rugged IP65 system • Easy-to-use touchscreen display and 3D animations • Core alignment tasks, including horizontal/vertical alignment, soft foot, twist/flatness, straightness, machine movement • Advanced alignment tasks: in-situ Cardan shaft, simultaneous coupling alignment, thermal growth monitoring, and more • Advanced software options: send out data in the field, cloud data transfer, analysis tools, monitoring and trend analysis
Even more concerning was that this test was conducted without any obstructions in the bearing housing outlet port, such as extension pipes and/or grease relief valves, which were permitted and even encouraged in the standard.
• Thermal growth monitoring: Includes capabilities to monitor and analyze thermal growth and pipe strain, allowing for more informed maintenance decisions.
• Measurement modes: The system offers various measurement modes, including single-point, multi-point, and continuous sweep, to accommodate different alignment scenarios.
Via the PRUFTECHNIK ROTALIGN touch Voice App you can easily control the ROTALIGN touch laser-shaft- and machine-alignment system due to voice-control connected with your mobile phone or tablet-pc based on a Bluetooth connection. Thus you can fully concentrate on measuring and dictate the machine dimension directly into the device without even touching it. Measuring modes can be switched by voice control, too. The PRUFTECHNIK ROTALIGN Voice App amends the shaft alignment process and makes it more effective. You save time, your hands are free for the alignment process and in the end, you receive a precise, reliable, and repeatable alignment result.
The Motor Running method should be the preferred lubrication procedure for grease-lubricated electric motors requiring relubrication.
The first series of static tests were conducted to evaluate the effectiveness of the two approved grease relief valves in controlling/minimizing grease entry into the motor in the Motor Stopped condition. The following test protocol was used:
Based on the results of these static tests, the remainder of the dynamic tests were conducted with the Gits cup directly connected to the bearing housing outlet.
A new IEEE 841 compliant motor (Frame 326T, 3,600 rpm) was supplied by the DuPont LaPorte THF area for the test. The motor was equipped with rotating labyrinth seals, open deep-groove ball bearings and grease relief valves on both motor bearing housings. A thermocouple was installed in contact with the output shaft bearing outer race to monitor bearing temperatures during the test.
A plausible explanation for this result is that in the normal running condition, the grease within the bearing housing is much softer and more pliable, thus offering less resistance to flow of excess grease within the bearing system. It now appears that the Motor Running lubrication method reduces/minimizes the amount of grease that purges into the motor internals, especially under full housing conditions and should be the preferred method of lubrication for grease-lubricated motors.
Whether it is a Cardan shaft, a vertical pump, or a turbomachine train, ROTALIGN touch will not let you down. All the best intelligent features are included: vertiSWEEP, Cardan Shaft, Live Trend, Live Move, Multicoupling Measure, Move, and Live Trend.
• Multi-coupling live trend: Allows for the monitoring of alignment changes over time across multiple couplings, providing valuable insights into machine behavior.
Fluke tools
Results and conclusions from this work were confirmed in the field and will be the basis for modification of a DuPont lubrication engineering standard covering electric motor lubrication.
ANSI tolerances available for Short flex and Spacer coupling typesResolution available in both 2DP and 3DP (Metric) Report print previewReport new section: Measurement equipment serial number and due calibration dateTolerance screen accessible directly from Results viewContext sensitive help ‘?’ button directly accessible within main workflow screens"Add feet" button available in stationary machine properties
In April 2002, with the assistance of our alliance motor vendor, and other DuPont engineering and mechanical specialists, a comprehensive testing program was carried out at the vendor's Baytown, Texas repair facility.
• Adaptive alignment: Integrates Active Situational Intelligence to automatically adjust to various alignment challenges, ensuring optimal performance.
• Integrated camera: RotAlign includes an integrated camera for documenting alignment conditions and surrounding area, useful for reporting and alignment verification.
RotAlign Touch is the flagship laser alignment tool from Prüftechnik, a complete system that delivers maximum value and ROI for your alignment work. • High-precision adaptive alignment, rugged IP65 system • Easy-to-use touchscreen display and 3D animations • Core alignment tasks, including horizontal/vertical alignment, soft foot, twist/flatness, straightness, machine movement • Advanced alignment tasks: in-situ Cardan shaft, simultaneous coupling alignment, thermal growth monitoring, and more • Advanced software options: send out data in the field, cloud data transfer, analysis tools, monitoring and trend analysis
• Simultaneous coupling alignment: Enables real-time adjustments on up to six couplings simultaneously, enhancing efficiency and accuracy during complex alignments.
Please ensure the touch device is charged or has at least 50% battery capacity.Unzip file to empty PRUFTECHNIK USB memory stick. Firmware is stored in "touch" folder.Switch on the touch device. Wait for Home screen to appear.Connect USB memory stick to the touch device USB port. New firmware copied from USB memory stick to the touch device.After approximately 1 minute on-screen message box appears stating new upgrade firmware found. Tap green tick button to start upgrade. Remove USB memory stick from the touch device.The touch device restarts and firmware upgrade begins.After completion of firmware upgrade the touch device restarts and finishes in Home screen.
• In-situ cardan shaft alignment: Offers specialized features for cardan shaft alignment without the need for disassembly, saving time and reducing effort.
At our work site we use the ROTALIGN touch laser instrument as a high-end system for shaft pump alignment. The system delivers the best measurement accuracy while offering the most innovative features that save you much time and effort.
The end bell was carefully reassembled and then a predetermined amount of grease, based on the bearing dimensions, was slowly added to the bearing housing.
The increase in temperature illustrated here may vary with different greases depending upon their chemical structure and physical properties as well as base oil viscosity.
Grease relief valves should be thought of as "excess lubricant indicators". If grease is observed exiting the port, bearing housings are full. Reduce the lubricant amount or increase the lubrication interval.
However there was much less grease inside the motor, because unlike the previous test, the grease relief valve functioned as designed. However, after collecting and weighing all the excess grease from inside the motor and that which was expelled from the Gits cup, approximately one-third of the grease exited the relief valve and two-thirds leaked inside the motor.
Performance of industry-leading polyurea grease vs. a competitive low-noise polyurea - effects of physical/chemical properties on lubrication performance
A considerable amount of grease migrated past the inner cap and flung off the rotating shaft onto the motor windings. A considerable amount of grease was also found in the drive end bell. No grease exited the grease relief valve during the test.
In this test condition, the motor, which was at ambient conditions and bearing housing 100 percent grease full, was started on the test bench and allowed to run at its no-load speed of 3,600 rpm. The drive end bearing temperature was recorded at one-minute intervals until the temperature plateaued and started to drop, indicating that the bearing housing had purged all the excess grease and reached an equilibrium condition.
Grease relief valves can reduce the amount of grease that enters the motor internals when relubrication is performed while the motor is running at steady-state operating temperature conditions.
The most important finding from this test was the fact that the grease relief valve system did function as designed and partially relieved the pressure in the bearing housing. This reduced the level of contamination in the motor cavity.
• Advanced diagnostics: Equipped with features like soft foot detection and correction, RotAlign helps identify and rectify common alignment issues, ensuring machinery operates at optimal efficiency.
This article reviews the results from laboratory testing of a grease-lubricated NEMA-frame, 3,600 rpm electric motor manufactured to IEEE 841 standards and equipped with open deep-groove ball bearings and grease relief valves on bearing housing outlets.
• Advanced software & cloud connectivity: Comes with full suite of software options, including cloud data transfer and comprehensive analysis tools, allowing for detailed monitoring and alignment trend analysis.
• User-friendly: Features an intuitive touchscreen interface with guided procedures, making complex alignment tasks more accessible to users of different skill levels (WiFi & Bluetooth connected)
Now, with our movement to the IEEE 841 standard design with its open bearing configuration, we became even more concerned about the feasibility of continuing to support the Motor Running lubrication method within our motor lubrication standard.
Again the outer race temperature was monitored and the motor components were inspected for excess grease after the test.
By checking this box, I agree to receive marketing communications and product offers by email from Fluke Electronics Corporation, transacting under Fluke, Fluke Connect, eMaint, Accelix, Pruftechnik, or its partners in accordance with its privacy policy.
Operating at or near full housing conditions will force grease into the windings after a Motor Stopped lubrication event.
• Vertical machine alignment: Features vertiSWEEP continuous measurement mode, specifically designed for precise vertical shaft alignment tasks.
The bearing temperature increased rapidly from a 70°F ambient to 120°F within the first minute of operation, then climbed steadily, reaching a maximum temperature of 176°F approximately 90 minutes into the test. The temperature then dropped slowly to a steady-state operating temperature of 152°F, approximately two and a half hours into the test.
The long temperature stabilization time indicted that the nominal 30-minute wait time in the lubrication standard may be inadequate for this relubrication method.
• Intelligent reporting: Offers detailed report generation capabilities, providing clear and concise documentation of alignment processes, results, and recommendations for maintenance actions.
Grease relief valves are most effective in preventing gross overlubrication in the Motor Stopped ambient temperature condition, but may not function during an ambient temperature restart, resulting in even more grease entering the motor internals.
Over the past few years, there has been a renewed interest in the industry regarding the proper lubrication methods for grease-lubricated electric motors.
The test was repeated using the same test protocol, but the Gits cup was replaced by an Alemite 314700 grease relief valve, rated at 1 psig opening pressure, and the same predetermined grease volume was again added to the bearing housing. The following results were obtained:
While two methods of relubrication were permitted in the DuPont standard, Motor Stopped and Motor Running, the Motor Stopped method was clearly preferred assuming that this was the best method to prevent overlubrication and damage to the windings. However, in actual practice, the Motor Running method is the predominant method used at the plant level, because operational demands precluded shutting down a piece of equipment for routine relubrication, as this could upset the process and cause an unanticipated plant shutdown.
RotAlign Touch delivers unrivaled precision and easy-of-use with cutting edge technology from the old pros in laser alignment, Prüftechnik.
By checking this box, I agree to receive marketing communications and product offers by email from Fluke Electronics Corporation, transacting under Fluke, Fluke Connect, eMaint, Accelix, Pruftechnik, or its partners in accordance with its privacy policy.
Another interesting observation during this test was the fact that grease pushed through the drive end labyrinth seal and small bits of grease were thrown against the inner cap retainer bolt heads and onto the working surfaces around the motor (Figure 3).
The Gits cup was judged slightly better than the Alemite fitting due to a larger bore opening in the fitting. Even after the grease gun was removed from the supply zerk fitting, grease continued to purge from the Alemite relief fitting for several seconds, which indicated residual pressure buildup in the bearing housing.
In August 2001, DuPont conducted tests at an authorized electric motor repair facility in the Mid-Atlantic area, which raised even more questions on the effectiveness of the Motor Running method in preventing/minimizing grease from entering the windings of an in-service motor.
As observed in the previous test, grease migrated through the gap between the inner cap and the motor shaft and either dripped or was flung off the shaft into the motor winding and end bell.
By checking this box, I agree to receive marketing communications and product offers by email from Fluke Electronics Corporation, transacting under Fluke, Fluke Connect, eMaint, Accelix, Pruftechnik, or its partners in accordance with its privacy policy.
From a practical perspective, this test condition simulated relubrication in the Motor Stopped condition and the grease relief valve did not function at all in this condition.
The sensALIGN Series technology is based on the inherent PRUFTECHNIK single-laser technology providing highly precise measurement results and easiest mounting and measuring in the field. sensALIGN 7 sensors include two HD large position-sensitive detectors (PSD) and MEMS inclinometers. Combined with the detector extension capability (InfiniRange), it is always possible to measure and document the initial alignment condition; no matter how big is the misalignment. Furthermore, this technology allows the simultaneous monitoring of the machine corrections in vertical and horizontal directions, starting from any angular position where the sensor comes to stop.
Motors can be equipped with either open-, single- or double-shielded deep-groove ball bearings depending upon the manufacturer's preferences. According to our motor lubrication standard, on motors equipped with shielded bearings, the shields are to be oriented toward the grease cavity in the end bells. All bearing housings are to be fitted with grease relief valves to prevent overlubrication and damage to the windings, as well as possible damage to shielded bearings should the bearing housings become full of grease. Use of a high-quality, polyurea-thickened, mineral base oil grease is recommended for general-purpose applications up to 3,600 rpm and ambient temperatures up to 40°C.
In the next test, 15 shots (3/4 ounce) of grease were added slowly to the stabilized, normal-operating motor using a standard hand-operated grease gun.
There was little difference in the performance of either relief valve in the cold static test: Gits cup (Figure 2a), Alemite fitting (Figure 2b). One valve discharged 16 grams of grease, the other 14 grams.