The experimental results presented in this study were obtained using an EIT system based on the AFE4300 analog front-end of Texas Instruments. This integrated circuit has eight ports for current injection and potential measurement [15]. The AFE4300 generates an alternating current of 50 kHz and 294.5 μArms through a voltage-controlled current source (VCC). The alternating signal is generated by an internal direct digital synthesizer (DSS) and a 6-bit and 1-MHz digital-to-analog converter (DAC). The potentials at the electrodes are measured by a demodulator, which can be configured to obtain only the amplitude of the sinusoidal signal (full-wave rectifier (FWR) mode) or the in-phase and quadrature (I/Q) components. Our experiments used the FWR mode because it is faster than the I/Q mode. The amplitudes are quantized to 16-bits using a delta-sigma analog-to-digital converter (ADC) with a clock frequency of 1 MHz [18]. The AFE4300 is connected to a PIC16F886 microcontroller, which in turn receives the injection and measurement patterns from a LabVIEW application through an HC06 Bluetooth module. The EBI system has a protection network composed of resistors and capacitors that eliminates the DC offset present in the current signals. The power to the EBI system is supplied by a 3.7V lithium polymer (LiPO) battery. The protection network, the current amplitude (294.5 μArms), and the LiPO power supply make this device compliant with the safety standard IEC60601 for medical equipment. Figure 4 shows the block diagram of the EIT system.

RESUMEN: La bioimpedancia eléctrica (EBI) es una técnica no invasiva para monitorear el volumen de la vejiga. Los índices EBI impedancia global (GI), método de relación de impedancia (IRM) y relación de cambio de voltaje (VCR) se han aplicado con éxito para detectar cambios en el volumen de objetos con conductividad constante pero desconocida. En este trabajo se utilizan experimentos simulados e in vitro para comparar el rendimiento de estos índices con respecto a un nuevo enfoque propuesto por algunos autores y denominado VCR modificado (MVCR). Los resultados experimentales indican que los índices GI, VCR, y MVCR se incrementan cuando aumenta el volumen del objeto estudiado. Por otro lado, no se observó una relación directa o inversa entre el IRM y el volumen. El coeficiente de variación, definido como el rango intercuartílico dividido por la mediana, fue menor para el MVCR, lo que indica que el enfoque propuesto es menos sensible al ruido de medición que los otros tres métodos.

Cleveland Clinic is a non-profit academic medical center. Advertising on our site helps support our mission. We do not endorse non-Cleveland Clinic products or services. Policy

Bacterial infections are one of the most common causes of sepsis. Fungal, parasitic and viral infections are also potential sepsis causes. You can get sepsis when an infection triggers a chain reaction throughout your body causing organ dysfunction.

EBI is a promising method for monitoring tissue state and the functioning of organs in-vivo [8-10]; This technology is increasingly employed in the estimating and monitoring of bladder volume [11]. Schlebusch and collaborators [6,7,12] proposed the GI approach, which is linear and negatively correlated with bladder volume. The GI requires the reconstruction matrix that relates the pixels of an electrical impedance tomography (EIT) image with the estimated conductivity [13,14]. GI is obtained by summing all pixel values of the image vector. Another alternative for volume estimation consists of the sum of orthonormal tetrapolar potential measurements obtained from electrodes located around a target area. Other alternatives for volume estimation consider the tetrapolar measurements obtained from electrodes located around a target area. According to [12] and [14], both IRM and VCR exhibit a high correlation between volume and the tetrapolar measurements of impedance and voltage, respectively. Unlike GI, these approaches do not require an image reconstruction algorithm.

T. Schlebusch, S. Nienke, S. Leonhardt, and M. Walter, “Bladder volume estimation from electrical impedance tomography,” Physiological Measurement, vol. 35, no. 9, Aug. 20, 2014. [Online]. Available: https://doi.org/10.1088/0967-3334/35/9/1813

The GI requires images of differential EIT (dEIT) [14-16], in which homogeneous (vh ) and nonhomogeneous vector measurements are considered, and differences between vh and are used in a dEIT reconstruction algorithm to calculate changes of the conductivity inside the object under study [6,12,14]. The variations in the potential for any frame f (with a range from 1 to Nf ) are calculated using Equation (1).

D. Leonhauser , C. Castelar, T. Schlebusch , M. Rohm, R. Rupp, and et al., “Evaluation of electrical impedance tomography for determination of urinary bladder volume: comparison with standard ultrasound methods in healthy volunteers,” BioMedical Engineering OnLine, vol. 17, no. 95, Jul. 13, 2018. [Online]. Available: https://doi.org/10.1186/s12938-018-0526-0

N. Yoshimura and M. B. Chancellor, “Differential diagnosis and treatment of impaired bladder emptying,” Reviews in urology, vol. 6, no. 1, 2004. [Online]. Available: https://www.ncbi.nlm.nih.gov/pmc/articles/PMC1472851/

It’s very important to quickly identify people with infections that may go on to develop sepsis. There are no strict criteria to diagnose sepsis. That’s why providers use a combination of findings — from a physical exam, lab tests, X-rays and other tests — to identify the infection (blood cultures) and diagnose sepsis.

Image

Https frs gov cz en ioff application Status

The first part of the present study was carried out through a finite element simulation, in which the bladder was represented by a sphere whose radius varied from 0.05 to 0.19 m with increments of 0.01 m. [Figure 5]. A ring of 8 electrodes was used to simulate current injection and the measurement of potentials. A previous work [20] shows details of this experiment.

B. H. Brown, “Electrical impedance tomography (eit): a review,” Journal of Medical Engineering & Technology, vol. 27, no. 3, Jul. 09, 2009. [Online]. Available: https://doi.org/10.1080/0309190021000059687

捷克 移民 局

Being the k-th element of the vectors , respectively, and ? is the number of voltage measures per frame. The pixel conductivity vector I f , and the matrix R f are calculated using the Graz algorithm for EIT (GREIT), which it is the most accepted for researchers to image reconstruction of dEIT [17]. R f has M rows (number of pixels of the conductivity image) and N columns. Hence, the vector I f and v f are related by Equation (2).

Healthcare providers used to organize sepsis into three stages: sepsis, severe sepsis and septic shock. Now, they identify the condition on a more fluid scale. This scale ranges from infection and bacteremia (bacteria in your bloodstream) to sepsis and septic shock, which can lead to dysfunction of multiple organs and even death.

The authors thank the support of the Automatic Group Research and Electronic and telecommunication faculty of Universidad del Cauca

M. Min and T. Parve, “Improvement of lock-in electrical bio-impedance analyzer for implantable medical devices,” IEEE Transactions on Instrumentation and Measurement, vol. 56, no. 3, Jun. 2007. [Online]. Available: https://doi.org/10.1109/TIM.2007.894172

Considering that the measurement system had eight ports and because voltages at the three electrodes are not measured (injection electrode, drain electrode, and the nearest neighbor of the injection electrode), each frame contains N=40 voltages measurements. The GI is calculated from a 2D dEIT image of 32 by 32 pixels, using a finite element model of 37,412 elements implemented in Electrical Impedance and Diffuse Optical Tomography Reconstruction Software (EIDORS).

IRM relates volume to change in impedance. This technique estimates volumes independently of the conductivity of the object under study. The three tetrapolar measurements required to calculate the impedance ratio are presented in Figure 1 [12]. The frontal measurement is used to calculate the backward measurement defines and the side measurement determines . According to[12], the greatest sensibility to impedance variations is obtained when the object under study is close to the contour electrodes because, in such a configuration, current densities are maximized. Therefore, increasing the volume of the object implies a greater change in the sensitivity of impedance measurements. IRM is defined by Equation (4).

At the same time, an abnormal chain reaction in your clotting system can cause blood clots to form in your blood vessels. This reduces blood flow to the different organs of your body and can cause significant damage or even failure.

S. Leonhardt , A. Cordes, H. Plewa, R. Pikkemaat, I. Soljanik, and et al., “Electric impedance tomography for monitoring volume and size of the urinary bladder,” De Gruyter, Nov. 22, 2011. [Online]. Available: https://doi.org/10.1515/BMT.2011.022

Https wwwmvcrcz mvcren

Providers will request a number of additional tests to identify your infection and any organ damage or dysfunction. These tests may include:

S. Madushan, “Low-cost, integrated analog front-end for weight-scale and body composition measurement check for samples: Afe4300,” Texas Instruments, Dallas, Texas, Tech. Rep.SBAS586B, Jun. 2012.

To reduce noise sensitivity, we propose to estimate volume using eight voltage measurements instead of one, and use the patterns indicated in Figure 3.

S. Hersek, H. Toreyina, C. N. Teague, M. L. Millard-Stafford, H. K. Jeong, and et al., “Wearable vector electrical bioimpedance system to assess knee joint health,” IEEE Transactions on Biomedical Engineering, vol. 64, no. 10, Oct. 2017. [Online]. Available: https://doi.org/10.1109/TBME.2016.2641958

More than 1.7 million people in the United States receive a diagnosis of sepsis each year. There are differences in sepsis rates among different demographic groups. Sepsis is more common among older adults, with incidence increasing with each year after the age of 65 years old.

M. Grossi and B. Riccó, “Electrical impedance spectroscopy (eis) for biological analysis and food characterization: a review,” Journal of Sensors and Sensor Systems, vol. 6, no. 2, Aug. 28, 2017. [Online]. Available: https://doi.org/10.5194/jsss-6-303-2017

The results obtained with the steel spheres and the saline solution show that |GI|-1, VCR, and MVCR are suitable approaches for volume monitoring when the conductivity of the object under study is unknown but constant. VCR had the highest sensitivity to volume variation, while MVCR had a small interquartile rank. Both VCR and MVCR are simpler to implement than |GI|-1 because they do not require image reconstruction algorithms. These results show the viability of doing long in-vivo volume estimation experiments using an EIT system with 8 electrodes and the MVCR approach.

With quick diagnosis and treatment, many people with mild sepsis survive. Without treatment, most people with more serious stages of sepsis will die. Even with treatment, 30% to 40% of people with septic shock, the most severe stage of sepsis, will die.

J. D. M. Sánchez, V. H. M. Leyton, and C. F. R. Rodas, “Effect of the injection and measurement patterns and the geometric distribution of electrodes in bladder volume estimation using electrical impedance tomography,” presented at XXIII Symposium on Image, Signal Processing and Artificial Vision (STSIVA), Popayan, Colombia, 2021.

Of the four approaches contemplated in this study, |GI|-1 has the lowest sensitivity to volume change, since, as indicated in Table 1, the variation between the medians of the three spheres is on the order of thousandths. On the other hand, VCR has the highest sensitivity to volume change, and MVCR has a volume sensitivity greater than GI and less than VCR [Table 1]. MVCR has the lowest coefficient of variation [Table 1]. These results show that MVCR is the best alternative for volume monitoring.

IRM, proposed in [12], estimates the volume of an object by employing three impedance measurements. This approach presents a higher sensibility when the object under study is close to the boundary electrodes. It implies that the application of IRM to little objects located far from the boundary electrodes is limited [12]. On the other hand, VCR [14] requires two nonhomogeneous and one homogeneous measurement to determine impedance changes. IRM, unlike VCR, does not require these two types of measurements. The accuracy of IRM and VCR indexes is highly dependent on the location of the electrodes [11,12]. The proposed MVCR approach employs redundant bioimpedance measurements based on the injection and measurement patterns proposed in [11], which are obtained by the system described in[15].

Providers may sometimes suspect sepsis at bedside using the set of sepsis criteria — a tool called quick sequential organ failure assessment (qSOFA). You may have sepsis if you have confirmed or probable infection and at least two of the following criteria:

Figure 11 shows the results of the IRM approach. The median values of the IRM measurements are different for the three spheres [Table 1]. Table 1 shows that the medium-sized sphere has the lowest median (1.12), while the small sphere has the largest median [47]. These results corroborate the limitation of IRM for small volume estimation, as indicated in [12]. These results make IRM unsuitable for bladder volume estimation.

Sepsis occurs when your immune system has a dangerous reaction to an infection. It causes extensive inflammation throughout your body that can lead to tissue damage, organ failure and even death. Many different kinds of infections can trigger sepsis, which is a medical emergency. The quicker you receive treatment, the better your outcome will be.

V. Yang, P. Aroul, and K. Wen, “Impedance measurement with the afe4300,” Texas Instruments, Dallas, Texas, Tech. Rep. SBAA202, Oct. 2013.

The infection leading to sepsis can start in many different parts of the body. Common sites and types of infections that can lead to sepsis include:

If you survive sepsis, you’ll more than likely need rehabilitation before returning home. Your body has been through a lot. Healthcare providers will help you restore your health, and you’ll slowly learn how to take care of yourself again. Even just sitting up and standing at first may be difficult, depending on your condition. You’ll work with a provider to get your body up and moving and practice getting yourself to the bathroom and bathing yourself. Once you’ve regained your strength and restored your mobility, you’ll be able to go home.

Your healthcare provider will help you develop a plan to continue in your recovery. At first, you’ll work on small, achievable goals such as bathing and dressing. You’ll work to rebuild your physical strength, but it’ll also be important to take care of your mental health. Talk to your family, friends and healthcare providers about how you’re feeling. It’ll take some time, but eventually, you should start to feel like yourself again.

Sepsis is your body’s extreme reaction to an infection. When you have an infection, your immune system works to try to fight it. But sometimes your immune system stops fighting the infection and starts damaging your normal tissues and organs, leading to widespread inflammation throughout your body.

Sepsis can affect anyone, but people with any kind of infection, especially bacteremia, are at a particularly high risk.

Sepsis treatment needs to begin immediately. The most important concern in sepsis protocol is a quick diagnosis and prompt treatment.

ABSTRACT: Electrical bioimpedance (EBI) is a non-invasive technique for monitoring bladder volume. The EBI approaches global impedance (GI), impedance ratio method (IRM), and voltage change ratio (VCR) have been successfully applied to detect changes in the volume of objects with constant but unknown conductivity. In this work, simulated and in-vitro experiments are used to compare the performance of these methods with respect to a new approach proposed by some authors and called modified VCR (MVCR). Experimental results indicated that GI, VCR, and MVCR indices increase when the volume of the object under study increases. On the other hand, no direct or inverse relationship between IRM and volume was observed. The coefficient of variation, defined as the interquartile range divided by the median of a set of measurements, was lower for MVCR, which indicates that the proposed approach is less sensitive to measurement noise than the other three methods.

Image

Sepsis is a life-threatening medical emergency caused by your body’s overwhelming response to an infection. Without urgent treatment, it can lead to tissue damage, organ failure and death.

C. Castelar , “Internal electrode bladder volume eit for routine urodynamic test application: An fem study using eidors framework,” presented at Proceedings of the 20th International Scientific Student Conference Poster, Prague, Czech, 2016.

The bioimpedance approaches (VCR, IRM, and MVCR) are used to detect changes in volume when the object conductivity under study remains constant, using only the potential measurements. Furthermore, these methods require less computational effort than the |GI|-1 approach, which requires solving the EIT inverse problem. In this study, the in-vitro performance of volume estimation indices based on constant conductivity and variable volume objects was analyzed. The effects of conductivity variation will be considered in subsequent studies, as well as in-vivo analysis of the GI, VCR, and MVCR approaches.

E. Martínez-Agulló, J. P. Burgués-Gasión, and J. M. Alapont-Alacreu, “Vejiga neurógena. conceptos básicos,” Cínicas Urológicas de la complutense, vol. 8, 2000. [Online]. Available: https://dialnet.unirioja.es/servlet/articulo?codigo=2039159

The in vitro experiments were performed in a cylindrical phantom with a radius of 15 cm and a height of 30 cm, which was filled with a 4 g/L saline solution. The 8 electrodes were symmetrically distributed around a ring surrounding the phantom. To simulate the bladder, three steel spheres with volumes of 0.028 ? 3 , 0.030 ? 3 , and 0.0314 ? 3 were placed one by one into the phantom. The center of each sphere was aligned with the center of the electrode ring. Also, the equator of the sphere and the ring of electrodes were in the same plane [Figure 6]. For each sphere, 30 voltage measurements were taken. The three data sets, one for each sphere, were used as the inputs for the volume estimation methods GI, IRM, VCR, and MVCR. For each method, the medians of the three data sets were compared with each other using the nonparametric Kruskal-Wallis test. This approach was used instead of an ANOVA test because of the non-normality of the data.

Because of this and other factors, research studies show varying rates of life expectancy after sepsis. These rates range widely but typically show that more than half of all sepsis survivors will die within five years.

Figures 10 and 11 show that for VCR and MVCR, the measurements of the spheres do not overlap, and Table 3 indicates that the median values for these approaches are significantly different for the three spheres. The proposed MVCR is an extension of the VCR that uses eight voltage measurements to reduce noise sensitivity. As can be seen from Tables 1 and 2, the quotient between the interquartile range and the median (coefficient of variation) is lower for MVCR [Table 2], which indicates that the proposed approach improves precision.

Schlebusch and collaborators [7] show that GI is inversely proportional to the volume of the object. In this work, the linear relationship between |GI|-1 and volume was confirmed for the in-vitro experiments [Figure 8]. The interquartile ranges, which were lower than 3.5E-4, reveal the low sensitivity of |GI|-1 to measurement noise [Table 1]. In addition, the Kruskal-Wallis test [Table 3] confirmed that the difference between the |GI|-1 values for each sphere was significant (p = 1.34E-8). These results are not in agreement with [13], where the researchers found that the GI has a reduced sensitivity to volume changes when a ring arrangement of electrodes is used. Therefore, our results suggest that |GI|-1 is a viable alternative for volume monitoring using 8 electrodes in a simple ring configuration, and adjacent patterns for injection and measurement.

If an infection such as blood poisoning (septicemia) triggered your condition, you may develop a sepsis rash on your skin. The rash makes your skin appear red and discolored. You may see small, dark-red spots on your skin.

D. Naranjo-Hernández, J. Reina-Tosina, and M. Min , “Fundamentals, recent advances, and future challenges in bioimpedance devices for healthcare applications,” Journal of Sensors, vol. 2019, Jul. 15, 2019. [Online]. Available: https://doi.org/10.1155/2019/9210258

Figures 8 to 11 show the box plot considering 30 measurements for each sphere. The dispersion of the data is caused by the electromagnetic interference resulting from coupling the system with the phantom since the metal-electrolyte interface generates spontaneous voltage fluctuations [21]. For each of the four indices compared in this study, medians, interquartile ranges, and coefficient of variation are presented in Tables 1 and 2. The p-values from Kruskal-Wallis test for differences between the medians of the estimated volumes are presented in Table 3. The differences were considered statistically significant when p < 0.05, which indicates the possibility of distinguishing between the three spheres.

In the above equation, V0 is the voltage obtained when the current is injected through electrodes 1 and 2, and the studied object has the lowest volume. Like VCR, the voltages Vi (i = 1 ... 8) are the potentials when the object is at its final volume [Figure 3]. Equations (3), (4), (5) and (6) show that IRM, VCR, and MVCR are dimensionless, just like GI.

VCR associates the voltage change with the volume of the object under study [11]. This is calculated considering one reference measurement (V0) and one perturbed measurement (V) (Equation (5)]. The first is obtained when the studied object has the lowest volume, while the second is when this object has its highest volume

Spinal cord injuries cause complications of the urinary system such as flaccid neurogenic bladder and spastic bladder, which generate a lack of coordination between bladder contraction and sphincter relaxation. These dysfunctions cause urinary tract infections and kidney stones due to loss of micturition sensation and vesicourethral reflux[1,2]. The aim of urodynamics is to analyze bladder filling and emptying for the diagnosis of pathologies of the urinary system. Uroflowmetry is a medically approved technique for urodynamic studies that measure the volume of urine expelled per unit of time. This non-invasive method is complemented by ultrasound measurements to detect post-micturition urine residuals. The main disadvantage of uroflowmetry is that it cannot be applied to people with loss of micturition sensation[3]. Cystomanometry is another urodynamics approach that evaluates intravesical pressure variations and the bladder volume through a catheter used to control bladder filling and to record intravesical pressure [4]. The drawback of Cystomanometry is its invasive nature. The most used procedure to help patients evacuate urine is urethral catheterization; however, it generates risks such as infections and kidney stones [5,6]. For the previous reasons, it is necessary to use portable equipment to assist patients in determining bladder filling and avoid unnecessary catheterization due to the underestimation of bladder volume [5-7].

Sepsis itself isn’t contagious — you can’t spread it to other people. But you can spread the infections that can cause sepsis.

Y. Li, Y. Peng, X. Yang, S. Lu, J. Gao, and et al., “Analysis of measurement electrode location in bladder urine monitoring using electrical impedance,” Journal of Sensors and Sensor Systems , vol. 18, no. 34, Mar. 22, 2019. [Online]. Available: https://doi.org/10.1186/s12938-019-0651-4

You’ll need to give your body, mind and soul time to recover. When you get home, you may experience some unpleasant symptoms. Physical effects may include:

If your provider diagnoses you with sepsis, they’ll usually place you in the intensive care unit (ICU) of the hospital for special treatment. You may receive the following treatment for sepsis:

Cleveland Clinic is a non-profit academic medical center. Advertising on our site helps support our mission. We do not endorse non-Cleveland Clinic products or services. Policy

W. A. Taweel and R. Seyam, “Neurogenic bladder in spinal cord injury patients,” Research and Reports in Urology, vol. 7, Jun. 10, 2015. [Online]. Available: https://doi.org/10.2147/RRU.S29644

W. Schafer, P. Abrams, L. Liao, A. Mattiasson, F. Pesce, and et al., “Good urodynamic practices: Uroflowmetry, filling cystometry, and pressure-flow studies,” Neurourology and Urodynamics, vol. 21, no. 3, 2002. [Online]. Available: https://doi.org/10.1002/nau.10066

T. Schlebusch , J. Orschulik, J. Malmivuo, S. Leonhardt , D. Leonhauser, and et al., “Impedance ratio method for urine conductivity-invariant estimation of bladder volume,” Journal of Electrical Bioimpedances, vol. 5, no. 1, Jan. 2014. [Online]. Available: https://doi.org/10.5617/jeb.895

Many people die in the months and years after surviving sepsis. But researchers don’t know if the increased risk of death is due to previously having sepsis or having an underlying health condition.

Sepsis is a life-threatening medical emergency. To avoid sepsis, make sure to get treatment for any infections immediately. If you delay treatment, a simple infection could lead to a deadly condition. If you have an infection that isn’t getting better or seems to be getting worse, seek medical care right away. Without treatment, sepsis can lead to severe complications and even death.

The interquartile ranges for |GI|-1, VCR, and MVCR [Table 1] show that it is feasible to discriminate between the three spheres. For the four methods, the Kruskal-Wallis test [Table 3] indicates that the differences between the medians of the estimates are significant. However, as presented in Table 1, there is no direct or inverse relationship between IRM medians and the volume of the spheres.

V. H. Mosquera, R. Bragós, A. Arregui, and C. F. Rengifo, “Implementation of a low cost prototype for electrical impedance tomography based on the integrated circuit for body composition measurement afe4300,” presented at Proceedings of the 11th International Joint Conference on Biomedical Engineering Systems and Technologies - BIODEVICES, Madeira, Portugal, 2018.

Ministry of Interior Czech Republic

T. Schlebusch and S. Leonhardt , “Effect of electrode arrangements on bladder volume estimation by electrical impedance tomography,” Journal of Physics: Conference Series, vol. 434, Apr. 2013. [Online]. Available: https://doi.org/10.1088/1742-6596/434/1/012080

In humans, each fluid and tissue have different electrical properties. EBI estimation is done by measuring the voltage signal generated by a constant amplitude alternating current injected through boundary electrodes [12]. In this work, the tetrapolar approach for EBI measurement [Figure 1] is used to calculate the IRM, VCR, and MVCR indexes. On the other hand, the distribution of bioimpedance in a cross-section of the body is estimated using EIT [Figure 2]. Then, GI index is calculated by adding the pixels of the EIT image [13,14]. The GI, IRM, VCR, and MVCR are explained below.

Palabras clave: Bioimpedancia, estimación de volumen, impedancia global, método de relación de impedancia, relación de cambio de voltaje.

With prompt treatment, many people with sepsis recover completely and return to leading normal lives. But others may experience long-term effects. You may develop complications such as:

Figure 7 shows that IRM has the lowest accuracy when compared to |GI|-1, VCR, and MVCR. The studies [11,14,15] show that both GI and VCR have good accuracy in the volume estimation of in-vivo ex, periments, which is consistent with the simulation results presented in Figures 7a, 7c, and 7d. The GI obtained the lowest error (-4.6E-4), followed by MVCR (1.8E-3) and VCR (2.2E-3). These values indicate that the proposed MVCR is a viable alternative for volume monitoring since, in addition to having a low error, it does not require computationally expensive image reconstruction algorithms, as is the case with GI.

M. A. Lindozo-Lopes and E. D. R. de Paula Lima, “Continuous use of intermittent bladder catheterization - can social support contribute?” Rev. Latino-Am. Enfermagem, vol. 22, no. 3, May-Jun. 2014. [Online]. Available: https://doi.org/10.1590/0104-1169.3268.2438

The performance of GI, IRM, VCR, and MVCR was evaluated using a cylindrical phantom and three steel spheres: small, medium, and large, with radii of 27.5, 35.0, and 37.5 mm, respectively. For each trial, only one sphere was placed in the tank. The Kruskal-Wallis test was used to determine whether the differences between measurements were statistically significant.