Thrust bearings | Bearing solutions for axial Loads - thrust bearing uses
2-boltflange bearing1'' bore
Example: A 100lb fan running at 1200RPM requires a 40,000 hour life. The Cr/P factor is 14.2. Multiplying that factor by the weight of the fan (14.2×100) will provide you the minimum required capacity of the bearing, in this case 1,402lbs. A bearing with a capacity larger than this will provide you with the 40,000 hours required.
Keep in mind that designed life and actual life will be different. Designed life calculations will never account for all the variables life throws at an application. The L10 calculation assumes ideal operating conditions, and we know those are few and far between. Some studies show that approximately 10% of bearings reach their calculated lifespan, though there are innumerable reasons for this.
Flange bearing3 bolt
Baart Industrial Group 4660 Pine Timbers, Suite 165 Houston, TX 77041 PRIVACY POLICY | TERMS & CONDITIONS | PRIVACY SETTINGS | WARRANTY | CREDIT APPLICATION | CREDIT TERMS | EMPLOYMENT APPLICATION © 2025 Baart Industrial Group. All Rights Reserved.
FlangeBlockBearing
2 BoltFlange Bearing
If you need to know what the bearing capacity needs to be for your application and have the imposed radial load, RPM, and an idea of how long the bearing needs to last, the table below can provide you with that answer. A simplified L10 life chart is found below, but neither includes every viable application or L10 life.
By running through these calculations and tables you’re providing yourself with both the amount of hours you can expect your bearing to run and also how safely under the allowable radial load your application is.
Flange bearingtypes
When selecting a bearing for an application, it is often helpful to know what the expected life will be. The standard industry measurement is L10 bearing life. This is the number of hours at a constant speed that a group of bearings will reach before 10% of bearings fail.
Units attach to sides of equipment using three bolts. Use with SA and SB inserts only. Set screw units have two set screws 120° apart in the inner ring. Eccentric locking collar units provide locking for one-directional applications. Features ductile iron housing, narrow inner ring bearing and full cover metal-shroud seals. Full contact rubber seals (2RS suffix and non-relubricatable units also available (remove G suffix). Styles include:
The formula and table below will provide a few critical pieces of information for your bearing application. It will provide you with the required capacity of the bearing and the maximum radial load you can impose.
Flange bearingdimensions
If you know your bearing’s dynamic capacity, imposed radial load, and RPM, you can calculate your own L10 bearing life. This gives you an idea as to how long you can expect your bearing to run.